DESCRIPTION

Switchgear (and circuit breakers) are obviously critical components in electrical distribution systems and their operation significantly affects the overall operation of the system. The workshop will discuss application, installation, maintenance and testing issues relating to medium and high voltage switchgear and circuit breakers. There will also be a coverage of low voltage switchgear. You will receive a thorough grounding in switchgear theory and standards. You will gain a solid understanding of the issues associated with the proper application, installation and maintenance of these critical items of equipment with an overriding emphasis on safety. This comprehensive and practical workshop emphasises medium voltage switchgear which represents most of the switchgear installed on electrical distribution systems. The focus here is on air blast, oil, SF6 and vacuum circuit breakers. Case studies covering the main manufacturer’s equipment will illustrate the important practical principles. Other power system protection components will be discussed as well to ensure that switchgear is understood in the correct context.

COURSE OBJECTIVESSAFE OPERATION & MAINTENANCE OF SWITCHGEAR
Delegates will learn about the following:

• Selection of appropriate type and rating of circuit breakers and switchgear
• Fundamentals of operation of switchgear
• Switchgear components (CTs, VTs, relays, cable terminations)
• Safe operational policies including safety rules and safety documents
• Diagnostic tools and test equipment
• Safe maintenance policies including safe working in switch rooms, indoor and outdoor substations

COURSE CONTENTS

SWITCHGEAR – ORIGINS & TYPES

  • Single line diagrams
  • Active and passive network components
  • Circuit breaker utilisation
  • Alternative forms of MV switchgear – ring main units, load breaking/fault making switches,
  • Fuse switches
  • HV fuses in combination with, and as alternative to circuit breakers
  • Auto-reclosers and auto-reclose operation

APPLICATION OF SWITCHGEAR

  1. Principles of current interruption
  2. Plain break circuit breakers
  3. Bulk and small oil volume circuit breakers
  4. Turbulator (explosion pot)
  5. Operating mechanisms
  6. Transfer earth circuit breakers
  7. Air break and air blast switchgear
  8. SF6 and Vacuum
  9. Switchgear in association with disconnectors
  10. Fixed and withdrawable designs
  11. Switchgear standards
  12. Factors affecting switchgear selection

SPECIFICATION OF SWITCHGEAR

  1. Switchgear rating – highest system and impulse withstand voltages, load and short circuit currents
  2. Simple and complex protection system
  3. Switchgear ancillaries, measurement CTs, VTs, relays
  4. Cable terminations
  5. Indoor and outdoor operation
  6. Substation and switch room layouts and design

SHORT CIRCUIT TESTING

  • Symmetrical and asymmetrical breaking
  • Make and break operations
  • Understanding test oscillograms

SAFETY POLICIES

  • General safety precautions and the use of personal protective equipment
  • Principles of safety rules
  • Principles of personnel authorisation
  • Operative training for safe operation of switchgear
  • Isolation in a circuit breaker context
  • Safety documentation
  • Operational and safety locking, caution and danger notices
  • Safe working in a substation environment
  • Safety interlocks
  • Substation alarms
  • Individual study task and presentation -safety policies in my company and how they might be improved

OPERATION OF MODERN SWITCHGEAR

ASSET MANAGEMENT IN A SWITCHGEAR CONTEXT

  • Principles of time and condition based asset management
  • Asset registers
  • Asset management systems

DIAGNOSTICS, TESTING & MAINTENANCE

  • Switchgear inspection methodologies
  • Partial discharge measurement and survey
  • Timing tests
  • Thermovision
  • Mechanisms of deterioration
  • Principles of circuit breaker maintenance
  • Maintaining oil circuit breakers
  • Contact maintenance and contact wipe
  • Oil testing
  • Maintaining vacuum circuit breakers
  • Maintaining SF6 circuit breakers
  • SOPs and DINs
  • Switchgear defects and defect control systems

WHO SHOULD ATTEND
This course is designed for personnel responsible for maintenance, testing and troubleshooting low voltage power circuit breakers, protective relays, breaker trip devices and switchgear panels. The lab provides students with the opportunity to work on a variety of low voltage circuit breakers.

Jadwal Pelatihan Berdiklat  :
• 24 sd 26 Januari 2017
• 14 sd 16 Februari 2017
• 29 sd 31 Maret 2017
• 11 sd 13 April 2017
• 8 sd 10 Mei 2017 dan 22 sd 24 Mei 2017
• 6 sd 8 Juni 2017
• 18 sd 20 Juli 2017
• 14 sd 16 Agustus 2017
• 18 sd 20 September 2017
• 10 sd 12 Oktober 2017
• 7 d 9 November 2017
• 4 sd 6 Desember2017 and 26 sd 28 Desember2017

Catatan : Jadwal tersebut dapat disesuaikan dengan kebutuhan calon peserta

Lokasi dan investasi Pelatihan Berdiklat :

• Yogyakarta, Hotel Dafam Malioboro (6.500.000 IDR / participant)
• Jakarta, Hotel Amaris Tendean (6.500.000 IDR / participant)
• Bandung, Hotel Golden Flower (6.500.000 IDR / participant)
• Bali, Hotel Ibis Kuta (7.500.000 IDR / participant)
• Surabaya, Hotel Amaris (6.000.000 IDR / participant)
• Lombok, Hotel Jayakarta(7.500.000 IDR / participant)

Catatan :  Apabila perusahaan membutuhkan paket in house training, anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan.

Informasi Kontak Pelatihan Berdiklat :

Mobile Phone Number : 0857 2919 0737 (Whatsapp) / 0852 9095 1223

E-mail :

  • Admin@berdiklat.com
  • Berdiklat@gmail.com
  • Berdiklattraining@gmail.com

Atau silahkan mengisi Formulir di bawah ini :

Be the first to comment

Leave a Reply

Alamat email Anda tidak akan dipublikasikan.


*